ECORR Systems helps boiler operators, facility managers, and maintenance professionals identify the right Cortec® water treatments, VpCI® corrosion inhibitors, cleaners, and wet or dry layup products for their systems.
Filter
Sort By
Cortec VmCI®-307 | Corrosion Inhibiting Powder | 100 lb VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-3...
Cortec VmCI®-307 | Corrosion Inhibiting Powder | 100 lb VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307 provides an extremely efficient dry method to protect metals within an enclosed space. The VmCI® vaporizes and adsorbs on all metal surfaces, reaching all exposed areas, including recessed sections and interior cavities. Meets MIL I-22110C. Cortec is a world leader in rust and corrosion removal...
Cortec VmCI®-307 | Corrosion Inhibiting Powder | 5 lbs VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307...
Cortec VmCI®-307 | Corrosion Inhibiting Powder | 5 lbs VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307 provides an extremely efficient dry method to protect metals within an enclosed space. The VmCI® vaporizes and adsorbs on all metal surfaces, reaching all exposed areas, including recessed sections and interior cavities. Meets MIL I-22110C. Cortec is a world leader in rust and corrosion removal and...
Cortec VmCI®-307 Corrosion Inhibiting Powder 50 lb. VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307 provides an...
Cortec VmCI®-307 Corrosion Inhibiting Powder 50 lb. VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307 provides an extremely efficient dry method to protect metals within an enclosed space. The VmCI® vaporizes and adsorbs on all metal surfaces, reaching all exposed areas, including recessed sections and interior cavities. Meets MIL I-22110C. Cortec is a world leader in rust and corrosion removal and protection....
Cortec VpCI® - 648 ™ | 5 Gal VpCI® - 648 ™ is a ready-to-use waterborne corrosion inhibitor liquid for wet layup of high-purity steam boilers. VpCI® - 648 ™ is effective at a very low...
Cortec VpCI® - 648 ™ | 5 Gal VpCI® - 648 ™ is a ready-to-use waterborne corrosion inhibitor liquid for wet layup of high-purity steam boilers. VpCI® - 648 ™ is effective at a very low dosage and provides contact and vapor-phase corrosion protection. VpCI® - 648 ™ can be easily added into feedwater or condensate lines. Application does not require the boiler to be drained or opened. Cortec Boiler Salamander VpCIs vaporize and absorb on all metal surfaces, reaching all recessed areas...
Cortec VpCI® - 648 ™ | 55 Gal VpCI® - 648 ™ is a ready-to-use waterborne corrosion inhibitor liquid for wet layup of high-purity steam boilers. VpCI® - 648 ™ is effective at a very low dosage...
Cortec VpCI® - 648 ™ | 55 Gal VpCI® - 648 ™ is a ready-to-use waterborne corrosion inhibitor liquid for wet layup of high-purity steam boilers. VpCI® - 648 ™ is effective at a very low dosage and provides contact and vapor-phase corrosion protection. VpCI® - 648 ™ can be easily added into feedwater or condensate lines. Application does not require the boiler to be drained or opened. Cortec VpCI® - 648 ™ VpCIs vaporize and absorb on all metal surfaces, reaching all recessed areas and...
Cortec VpCI® - 649 Series ™ | 5 Gal Cortec’s VpCI® - 649 Series ™ is a ready-to-use waterborne corrosion inhibitor for wet-dry layup of boiler systems. Its combination of contact and Vapor...
Cortec VpCI® - 649 Series ™ | 5 Gal Cortec’s VpCI® - 649 Series ™ is a ready-to-use waterborne corrosion inhibitor for wet-dry layup of boiler systems. Its combination of contact and Vapor phase Corrosion Inhibitors protects multi-metal surfaces below and above the water level. VpCI® - 649 Series ™ is easy to apply because it does not require the boiler to be drained or opened for application. It is an excellent alternative to other methods of long-term layup. Cortec VpCI® - 649...
Cortec VpCI® - 649 Series ™ | 55 Gal Cortec’s VpCI® - 649 Series ™ is a ready-to-use waterborne corrosion inhibitor for wet-dry layup of boiler systems. Its combination of contact and...
Cortec VpCI® - 649 Series ™ | 55 Gal Cortec’s VpCI® - 649 Series ™ is a ready-to-use waterborne corrosion inhibitor for wet-dry layup of boiler systems. Its combination of contact and Vapor phase Corrosion Inhibitors protects multi-metal surfaces below and above the water level. VpCI® - 649 Series ™ is easy to apply because it does not require the boiler to be drained or opened for application. It is an excellent alternative to other methods of long-term layup. Cortec VpCI® -...
Cortec VpCI® Boiler Egg™ Cortec’s Boiler Egg™ is designed to scavenge oxygen and passivate metal during the initial filling of makeup water after seasonal or long-term dry layup of boilers. The...
Cortec VpCI® Boiler Egg™ Cortec’s Boiler Egg™ is designed to scavenge oxygen and passivate metal during the initial filling of makeup water after seasonal or long-term dry layup of boilers. The Boiler Egg™ comes in an easy-to-handle pouch that is readily dissolved upon water contact, releasing the active ingredients as the boiler is being filled. It protects against the threat of oxygen pitting during the critical startup phase of a boiler when the makeup water is normally not pre-heated...
Cortec VpCI® Boiler Lizard® | 1 Water Soluble Bag Boiler Lizard® contains VpCI® powder in a polyvinyl alcohol (PVA) water-soluble bag. The powder formulation is free of phosphates,...
Cortec VpCI® Boiler Lizard® | 1 Water Soluble Bag Boiler Lizard® contains VpCI® powder in a polyvinyl alcohol (PVA) water-soluble bag. The powder formulation is free of phosphates, heavy metals, nitrites and free amines. Designed for dry lay-up of boilers, the Boiler Lizard® powder protects metals in enclosed spaces. Protects up to 1000 gallons system capacity. Cortec Boiler Lizard® VpCIs vaporize and absorb on all metal surfaces, reaching all recessed areas and interior...
ECORR Systems provides Cortec® VpCI® corrosion protection solutions for industrial boiler systems, commercial heating plants, power-generation facilities, manufacturing operations, institutional facilities, and boiler service companies. These products help protect boilers and related equipment from corrosion during operation, inspection, maintenance, seasonal shutdown, standby, and long-term layup.
As an Authorized Cortec® Distributor, ECORR Systems offers boiler water treatment products, Vapor phase Corrosion Inhibitors, cleaners, rust and scale removers, protective coatings, and wet and dry layup solutions designed to support reliable boiler maintenance and asset preservation.
Boiler systems are exposed to water, oxygen, heat, dissolved solids, changing operating conditions, and chemical contaminants that can contribute to corrosion and scale formation. During shutdown, the remaining moisture and oxygen inside a boiler can create an especially aggressive environment for unprotected metal surfaces.
Corrosion may affect boiler tubes, drums, headers, waterside surfaces, fireside areas, feedwater systems, deaerators, condensate return lines, heat exchangers, and associated piping. Rust and corrosion products can restrict flow, contaminate the system, delay startup, reduce heat-transfer efficiency, and shorten the usable life of valuable equipment.
Cortec® VpCI® technology helps protect metal by forming a molecular corrosion-inhibiting layer on exposed surfaces. In compatible boiler applications, Vapor phase Corrosion Inhibitors can migrate through enclosed spaces to protect recessed areas, internal cavities, and metal surfaces above the waterline that conventional contact-only treatments may not reach.
Cortec® offers solutions for operating water systems, dry boiler layup, wet boiler layup, hydrostatic testing, startup protection, equipment cleaning, and long-term preservation. The appropriate product and treatment method depend on the boiler design, metallurgy, operating pressure, water chemistry, shutdown period, and required return-to-service time.
Dry layup is commonly used when a boiler will remain offline for an extended period and rapid startup is not required. Even after draining, residual moisture and humid air can remain inside the boiler and create conditions that promote corrosion.
Cortec® dry layup products use Vapor phase Corrosion Inhibitor technology to distribute protective vapors throughout enclosed boiler spaces. Depending on the boiler size, metal types, and area being protected, dry layup options may include Boiler Gecko™, Boiler Lizard®, Boiler Lizard® Plus, Boiler Dragon™, and other boiler-preservation products.
Some Cortec® dry layup products are supplied in water-soluble packaging or formulated for fogging into the boiler. Product selection and removal requirements must be confirmed for the waterside, fireside, boiler volume, system metallurgy, and planned recommissioning procedure.
Wet layup may be preferred for standby boilers that must return to service quickly or for systems where completely draining and drying the equipment is impractical. However, untreated water, dissolved oxygen, and unprotected headspace above the waterline can increase the risk of corrosion during the shutdown period.
Cortec® offers wet layup corrosion inhibitors designed to circulate through compatible boiler systems and provide protection below the waterline, at the air-water interface, and within enclosed headspace. Available options may include VpCI® Iguana, VpCI® Salamander, VpCI® Turtle, VpCI® Chameleon™, and other application-specific water treatment products.
Effective wet layup requires the selected treatment to be properly distributed throughout the boiler and connected system. Dosage, circulation, water chemistry, steam use, metallurgy, and discharge requirements should be evaluated before selecting a product.
Existing rust, scale, mineral deposits, oil, and process contamination may need to be removed before a boiler is inspected, repaired, treated, or placed into layup. Proper cleaning helps expose the underlying metal and supports more effective inspection and corrosion protection.
Cortec® offers cleaners, rust removers, and scale-removal products for compatible boiler components and water systems. The correct cleaning procedure depends on the deposit, base metal, system construction, operating history, wastewater requirements, and boiler manufacturer’s recommendations.
» Boiler Water Treatment and Corrosion Inhibitor Additives For compatible boiler water, condensate, closed-loop, hydrostatic testing, startup, and system-preservation applications.
» Boiler Layup and Equipment Preservation Products For protecting boiler waterside and fireside surfaces during seasonal shutdown, standby, maintenance, and long-term storage.
» Boiler Cleaners, Rust Removers, and Descalers For removing compatible rust, scale, mineral deposits, oils, and contaminants before inspection, treatment, or recommissioning.
» Rust Preventatives and Protective Coatings For external boiler components, maintenance equipment, replacement parts, structural steel, and exposed metal surfaces requiring direct protection.
» VpCI® Papers, Films, and Emitters For protecting boiler replacement parts, controls, electrical enclosures, tools, valves, fittings, and maintenance components during storage and shipment.
Cortec® boiler corrosion protection products can help facilities reduce rust during shutdown, simplify boiler preservation, protect internal surfaces, and support a smoother return to service. Proper layup can also help reduce corrosion-related cleaning, repairs, plugged components, startup delays, and premature equipment replacement.
Cortec® offers alternatives to traditional preservation practices such as desiccants, continuous dry-air systems, nitrogen blanketing, and certain conventional layup chemicals. Depending on the application, Cortec® products may reduce monitoring requirements, simplify application, and eliminate some of the labor associated with removing traditional preservation materials before startup.
Boiler layup is not limited to equipment that remains unused for an entire season. Corrosion protection may be appropriate whenever a boiler is drained, opened, placed on standby, taken offline for repairs, or exposed to humid conditions without its normal operating water treatment program.
ECORR Systems is an Authorized Cortec® Distributor helping boiler operators, facility managers, water treatment professionals, maintenance contractors, engineers, and industrial buyers identify suitable corrosion-control products for boiler systems and related equipment.
Whether you need a dry layup product, wet layup treatment, boiler water additive, rust remover, descaler, protective coating, or guidance for preserving replacement parts, ECORR Systems can help evaluate the boiler volume, metallurgy, water chemistry, operating conditions, shutdown duration, application method, and recommissioning requirements.
A boiler can retain moisture after it is drained or opened for maintenance. When this moisture combines with oxygen inside the system, unprotected steel surfaces may begin to corrode. Condensation, untreated makeup water, process contamination, and changing temperatures can increase the risk.
Dry layup generally involves draining the boiler and protecting the internal surfaces while the system remains offline. Wet layup keeps the boiler filled with treated water so it can usually return to service more quickly. The correct method depends on the shutdown duration, boiler design, operating requirements, and available maintenance procedures.
Cortec® dry layup options may include Boiler Gecko™, Boiler Lizard®, Boiler Lizard® Plus, Boiler Dragon™, and other VpCI® products selected according to boiler size, metallurgy, and whether waterside or fireside surfaces are being protected.
Requirements vary by product. Certain Cortec® boiler layup products can tolerate some residual moisture, while others require specific preparation and application conditions. Standing water, system cleanliness, product placement, and the manufacturer’s technical instructions must be considered before treatment.
Certain Cortec® boiler treatments contain Vapor phase Corrosion Inhibitors that migrate through enclosed headspace and form a protective molecular layer on metal surfaces above the treated water. This can provide an advantage over contact-only inhibitors that protect only submerged surfaces.
Removal requirements depend on the specific product and where it is applied. Some waterside products are designed to dissolve when the boiler is refilled, while products used on fireside surfaces or in sensitive systems may require removal or another defined recommissioning procedure. Always follow the applicable product data sheet and boiler operating requirements.
Product selection must account for how the steam will be used and whether it may contact food, pharmaceuticals, process materials, or high-purity equipment. Only a product specifically approved for the intended application should be used, and all applicable regulatory, plant, and boiler-manufacturer requirements must be followed.
Yes. ECORR Systems can help review the boiler type, internal volume, metallurgy, water chemistry, operating pressure, shutdown duration, layup method, steam use, and startup requirements to identify an appropriate Cortec® corrosion protection product.