ECORR Systems helps tank owners and industrial facilities identify Cortec® corrosion inhibitors, tank-bottom solutions, hydrotest additives, coatings, cleaners, and layup products for storage tanks and related equipment.
Filter
Sort By
Cortec Corrverter VpCI® Rust Converter Primer | 1 Gal CorrVerter® is a fast drying, water-based one-coat system (primer) that converts rusted surfaces to a hydrophobic passive layer and...
Cortec Corrverter VpCI® Rust Converter Primer | 1 Gal CorrVerter® is a fast drying, water-based one-coat system (primer) that converts rusted surfaces to a hydrophobic passive layer and prevents further rusting thru the unique formulation of chelating agents and PVDC resins. UFI: FM30-30MW-500H-F6AX Cortec is a world leader in rust and corrosion removal and protection. Cortec VpCI® products offer cost-effective and environmentally friendly corrosion protection solutions that are...
Cortec Corrverter VpCI® Rust Converter Primer | 5 Gal CorrVerter® is a fast drying, water-based one-coat system (primer) that converts rusted surfaces to a hydrophobic passive layer and...
Cortec Corrverter VpCI® Rust Converter Primer | 5 Gal CorrVerter® is a fast drying, water-based one-coat system (primer) that converts rusted surfaces to a hydrophobic passive layer and prevents further rusting thru the unique formulation of chelating agents and PVDC resins. UFI: FM30-30MW-500H-F6AXCortec is a world leader in rust and corrosion removal and protection. Cortec VpCI® products offer cost-effective and environmentally friendly corrosion protection solutions that are...
Cortec VmCI®-307 | Corrosion Inhibiting Powder | 100 lb VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-3...
Cortec VmCI®-307 | Corrosion Inhibiting Powder | 100 lb VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307 provides an extremely efficient dry method to protect metals within an enclosed space. The VmCI® vaporizes and adsorbs on all metal surfaces, reaching all exposed areas, including recessed sections and interior cavities. Meets MIL I-22110C. Cortec is a world leader in rust and corrosion removal...
Cortec VmCI®-307 | Corrosion Inhibiting Powder | 5 lbs VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307...
Cortec VmCI®-307 | Corrosion Inhibiting Powder | 5 lbs VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307 provides an extremely efficient dry method to protect metals within an enclosed space. The VmCI® vaporizes and adsorbs on all metal surfaces, reaching all exposed areas, including recessed sections and interior cavities. Meets MIL I-22110C. Cortec is a world leader in rust and corrosion removal and...
Cortec VmCI®-307 Corrosion Inhibiting Powder 50 lb. VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307 provides an...
Cortec VmCI®-307 Corrosion Inhibiting Powder 50 lb. VmCI®-307 powder protects both ferrous and non-ferrous metals from corrosion in recessed areas, interior cavities and voids. VmCI®-307 provides an extremely efficient dry method to protect metals within an enclosed space. The VmCI® vaporizes and adsorbs on all metal surfaces, reaching all exposed areas, including recessed sections and interior cavities. Meets MIL I-22110C. Cortec is a world leader in rust and corrosion removal and protection....
Cortec VpCI® S-49 | Fuel Additive | 55 Gal S-49 is a fuel oil dispersant/emulsifier that keeps insoluble particles dispersed, thus reducing carbon deposits on tips, soot formations, smoke...
Cortec VpCI® S-49 | Fuel Additive | 55 Gal S-49 is a fuel oil dispersant/emulsifier that keeps insoluble particles dispersed, thus reducing carbon deposits on tips, soot formations, smoke emissions, particulate emissions and sludge deposits in fuel storage tanks. S-49 is a blend of solvents, dispersants, surfactants and emulsifiers for treatment of fuel oil grades 2, 4, 5 and 6. Cortec is a world leader in rust and corrosion removal and protection. Cortec VpCI® products offer...
Cortec VpCI®-308 | Corrosion Inhibiting Powder | 100 lbs VpCI®-308 powder form for corrosion protection of ferrous and non-ferrous metals in recessed areas, interior cavities and voids. In...
Cortec VpCI®-308 | Corrosion Inhibiting Powder | 100 lbs VpCI®-308 powder form for corrosion protection of ferrous and non-ferrous metals in recessed areas, interior cavities and voids. In addition to enhanced multimetal protection and water solubility, VpCI®-308 is a biodegradable product. When required VpCI®-308 in powder form can be removed by using blown air or by a water rinse. Typically, when applied in aqueous form the product does not require removal. Commercial equivalent to MIL...
Cortec VpCI®-308 | Corrosion Inhibiting Powder | 5 lbs VpCI®-308 powder form for corrosion protection of ferrous and non-ferrous metals in recessed areas, interior cavities and voids. In...
Cortec VpCI®-308 | Corrosion Inhibiting Powder | 5 lbs VpCI®-308 powder form for corrosion protection of ferrous and non-ferrous metals in recessed areas, interior cavities and voids. In addition to enhanced multimetal protection and water solubility, VpCI®-308 is a biodegradable product. When required VpCI®-308 in powder form can be removed by using blown air or by a water rinse. Typically, when applied in aqueous form the product does not require removal. Commercial equivalent to MIL...
Cortec VpCI®-308 | Corrosion Inhibiting Powder | 50 lbs VpCI®-308 powder form for corrosion protection of ferrous and non-ferrous metals in recessed areas, interior cavities and voids. In...
Cortec VpCI®-308 | Corrosion Inhibiting Powder | 50 lbs VpCI®-308 powder form for corrosion protection of ferrous and non-ferrous metals in recessed areas, interior cavities and voids. In addition to enhanced multimetal protection and water solubility, VpCI®-308 is a biodegradable product. When required VpCI®-308 in powder form can be removed by using blown air or by a water rinse. Typically, when applied in aqueous form the product does not require removal. Commercial equivalent to MIL...
ECORR Systems provides Cortec® VpCI® corrosion protection solutions for aboveground storage tanks, tank farms, process vessels, fuel tanks, water tanks, and related equipment. These products help protect internal surfaces, tank-bottom plates, interstitial spaces, piping, valves, and stored components during construction, hydrostatic testing, operation, shutdown, maintenance, and long-term layup.
As an Authorized Cortec® Distributor, ECORR Systems offers VpCI® powders, fogging fluids, water-treatment additives, rust removers, cleaners, temporary coatings, packaging products, and engineered CorroLogic® solutions for storage tank corrosion protection.
Storage tanks may be exposed to water, condensation, oxygen, chlorides, acidic gases, process chemicals, fuel contaminants, microorganisms, soil conditions, and changing temperatures. Corrosion can develop inside the tank, beneath the floor, between double bottoms, under insulation, or on external surfaces.
Because many affected surfaces are hidden or difficult to inspect, corrosion may continue unnoticed until it causes product contamination, wall or floor thinning, leaks, repairs, environmental concerns, or an unplanned shutdown.
Cortec® VpCI® technology uses Vapor phase Corrosion Inhibitors that diffuse through enclosed spaces and form a protective molecular layer on accessible metal surfaces. This vapor-phase action helps protect recessed areas, internal cavities, tank headspace, interstitial spaces, and irregular surfaces that may be difficult to reach with conventional coatings.
Depending on the application, Cortec® products may be introduced as powders, liquids, fogging treatments, water additives, slurries, direct-applied coatings, emitters, or corrosion-inhibiting packaging.
The proper solution depends on the tank design, stored product, metallurgy, temperature, water content, internal condition, tank-bottom configuration, operating status, and required protection period.
The underside of an aboveground storage tank floor is one of the most difficult areas to inspect and protect. Moisture, chlorides, soil conditions, foundation materials, and contaminants can create a corrosive environment beneath the tank.
Tank floors may not remain in uniform contact with the underlying pad. Irregularities, settlement, welding distortion, and movement caused by filling and emptying can create small voids where moisture and corrosive contaminants accumulate.
CorroLogic® VpCI® systems introduce Vapor phase Corrosion Inhibitors beneath the tank floor. The inhibitors diffuse through the interstitial space and form a protective molecular layer on accessible soil-side steel surfaces, including areas that may not remain in direct contact with the tank pad.
CorroLogic® can be incorporated into the design and construction of a new aboveground storage tank or installed as part of an existing tank’s corrosion-management program. Available application methods may include CorroLogic® Powder, Slurry, or engineered injection and distribution systems.
For some existing tanks, CorroLogic® materials can be introduced beneath the tank floor through properly designed injection points without raising or emptying the tank. Feasibility depends on tank construction, foundation design, access, operating conditions, and applicable facility requirements.
CorroLogic® installation should be designed and performed by qualified corrosion professionals and authorized applicators.
Cathodic protection is commonly used to control soil-side corrosion on aboveground storage tank bottoms. Its effectiveness depends on electrical continuity, system condition, tank-bottom contact, anode performance, current distribution, and monitoring.
Vapor phase Corrosion Inhibitors may be used as a complementary layer of protection in areas where contact with the cathodically protected pad is uneven or where voids exist beneath the tank floor. VpCI® technology does not require a continuous electrical power source to establish its protective molecular layer.
The relationship between VpCI® treatment and cathodic protection must be evaluated for the specific tank. Neither method eliminates the need for inspection, integrity management, leak detection, or regulatory compliance.
Vapor corrosion inhibitor technology for aboveground storage tank bottoms is addressed by industry guidance, including API Technical Report 655, Vapor Corrosion Inhibitors for Storage Tanks. AMPP SP21474-2023 also addresses external corrosion control for on-grade carbon-steel storage tank bottoms.
These documents provide industry context but do not replace tank-specific engineering, regulatory requirements, inspection standards, or the owner’s integrity-management program.
Internal corrosion may occur when water, oxygen, salts, sludge, acidic contaminants, or process materials contact the tank wall, floor, roof, internal supports, or other components. Corrosion risk may be especially high at the product-water interface and in the headspace above the stored liquid.
Cortec® offers product-specific corrosion inhibitors for selected fuel, oil, water, brine, and process applications. Certain formulations can provide protection in the liquid phase, at the liquid-vapor interface, and within the tank headspace.
Compatibility with the stored product, tank lining, seals, filtration, downstream process, and applicable regulations must be confirmed before adding any corrosion inhibitor to a storage tank.
Tank headspace can contain humid air and corrosive vapors that condense on the roof, shell, internal supports, and metal surfaces above the liquid level. Contact-only inhibitors in the stored liquid may not reach these areas.
Cortec® VpCI® fogging fluids and powders can establish a corrosion-inhibiting atmosphere inside compatible empty tanks, void spaces, and enclosed vessels. The inhibitors migrate through the headspace and protect accessible metal surfaces without requiring direct application to every area.
The tank should be sufficiently enclosed to retain the required vapor concentration. Tank volume, internal configuration, ventilation, contamination, temperature, and exposure period must be considered when calculating treatment.
A tank that has been emptied for inspection, maintenance, reduced production, or long-term shutdown can corrode rapidly if moisture and contaminants remain inside. Temperature changes may also create condensation after the tank appears dry.
A tank-layup program may include:
Some tanks remain filled with water or another compatible fluid during standby. In these applications, the treatment must protect submerged surfaces, the air-water interface, and exposed metal within the headspace.
Cortec® water-treatment products provide options for compatible wet-layup applications. Proper mixing and distribution are important so the inhibitor reaches all areas of the system.
Water chemistry, tank metallurgy, existing coatings, temperature, biological activity, retained fluid, discharge requirements, and planned return to service should be evaluated before treatment.
Hydrostatic testing introduces water into new, repaired, or inspected tanks. Even after draining, water can remain along floor irregularities, seams, nozzles, supports, and other difficult-to-dry areas.
Cortec® corrosion inhibitors can be added to compatible hydrotest water to help protect ferrous and non-ferrous metals during testing and the period between testing and commissioning. Selected products offer contact and vapor-phase protection.
Product selection depends on water quality, chloride content, hardness, metallurgy, existing coatings, test duration, discharge requirements, and the tank’s final service.
New tanks may remain exposed for months between fabrication, hydrotesting, coating, inspection, and commissioning. Open nozzles, incomplete roofs, rain, salt air, blowing dust, and temperature changes can expose unprotected metal to corrosion.
Temporary protection may include hydrotest additives, internal fogging, VpCI® powder, removable coatings, flange protection, VpCI® packaging, and protective covers. The preservation method should remain compatible with welding, coating, inspection, cleaning, and commissioning requirements.
Fuel and petroleum tanks can accumulate water through condensation, product contamination, or operational conditions. Water settling at the tank bottom may contribute to corrosion, sludge formation, and microbial activity.
Cortec® offers product-specific corrosion inhibitor additives for compatible fuel, petroleum, and oil-storage applications. Some formulations provide contact protection within the stored liquid and vapor-phase protection above the fluid level.
Fuel specification, downstream equipment, combustion performance, filtration, seals, coatings, regulatory requirements, and additive approvals must be reviewed before treatment.
Water-storage and fire-water tanks may remain filled for extended periods. Dissolved oxygen, chlorides, changing water levels, and microbiological activity can contribute to internal corrosion.
Cortec® offers inhibitors for selected industrial-water and fire-water systems. Potable-water tanks require products specifically approved for that use and must comply with all applicable health, water-quality, and facility requirements.
Double-bottom storage tanks contain an enclosed space between the original floor and the replacement or secondary floor. Moisture entering this space may create corrosion on surfaces that are difficult to inspect or coat.
Vapor phase Corrosion Inhibitors can be introduced into the interstitial space to establish a protective environment. Distribution, sealing, drainage, monitoring points, leak-detection systems, and compatibility with the tank design should be evaluated before application.
External tank surfaces are exposed to rain, humidity, sunlight, salt spray, industrial pollutants, and changing temperatures. Roof plates, stairways, handrails, nozzles, fasteners, supports, and other components may require additional corrosion protection during construction or maintenance.
Cortec® offers temporary and longer-term coatings for compatible exterior metal surfaces. Product selection depends on substrate preparation, exposure, ultraviolet resistance, film thickness, appearance, temperature, and required service life.
Temporary coatings should not automatically be considered replacements for permanent tank-coating systems.
Tank valves, flanges, nozzles, manways, bolts, and gaskets may be exposed during fabrication, shutdown, or maintenance. Machined flange faces are particularly vulnerable because corrosion or pitting can interfere with proper sealing.
Cortec® removable coatings, lubricants, VpCI® films, papers, covers, and protective caps can help preserve these components. Compatibility with gasket materials, stored products, operating temperature, and recommissioning procedures should be confirmed.
Product residue, sludge, oil, grease, salts, rust, and scale may need to be removed before inspection, repair, coating, or preservation. Cleaning requirements depend on the previous tank contents and the work being performed.
Cortec® offers industrial cleaners, degreasers, rust removers, and scale-removal products for compatible metals and tank applications. Some cleaners contain corrosion inhibitors to help reduce flash rust after cleaning.
Tank entry, cleaning, ventilation, waste handling, confined-space procedures, and atmospheric testing must be performed according to applicable facility and regulatory requirements.
Temporary coatings can protect tank components during fabrication, shipment, outdoor staging, maintenance, and shutdown. Cortec® offers water-based, solvent-based, wax-like, removable, oily, and dry-film rust preventatives for different environments.
Products such as VpCI®-368 provide removable protection for harsh outdoor conditions, while VpCI®-391 provides a water-based, dry, non-tacky protective film for compatible metal surfaces.
Tank farms and industrial facilities may keep valves, pumps, seals, gauges, instrumentation, fasteners, and other critical parts in storage. These components must remain protected and ready for maintenance or emergency use.
A preservation program may combine cleaning, rust preventatives, corrosion-inhibiting lubricants, VpCI® films, bags, papers, emitters, foams, and protective caps. Stored items should be labeled with the treatment date, product used, inspection schedule, and removal requirements.
» Tank, Fuel, Oil, and Water Corrosion Inhibitors For compatible storage fluids, hydrostatic testing, wet layup, fuels, oils, industrial water, and internal tank-preservation applications.
» Tank Coatings and Rust Preventatives For compatible tank components, flange faces, nozzles, manways, valves, external surfaces, and equipment exposed during construction or storage.
» Industrial Cleaners and Rust Removers For removing compatible oils, grease, residue, rust, scale, and contamination before inspection, coating, repair, or preservation.
» Corrosion-Inhibiting Lubricants and Greases For compatible valves, fasteners, hinges, actuators, pumps, bearings, and tank-maintenance equipment.
» Tank Layup and VpCI® Packaging Products For empty tank interiors, enclosed voids, valves, replacement parts, maintenance equipment, storage, and shipment.
A storage tank corrosion-control plan should begin with the tank design, metallurgy, service history, stored product, inspection results, foundation, existing coatings, cathodic protection, and environmental conditions.
Important considerations include:
ECORR Systems is an Authorized Cortec® Distributor helping tank owners, terminal operators, industrial facilities, engineers, contractors, maintenance teams, and corrosion professionals identify appropriate storage tank corrosion-control products.
Whether you need a hydrotest additive, internal fogging product, tank-bottom corrosion solution, removable coating, cleaner, rust remover, lubricant, or VpCI® packaging for tank components, ECORR Systems can help evaluate the tank, metallurgy, stored product, exposure conditions, application method, and required protection period.
Corrosion may develop on internal walls and floors, in the headspace, beneath the exterior tank bottom, between double bottoms, under insulation, on the roof and shell, or on valves, flanges, nozzles, and related components.
CorroLogic® products release Vapor phase Corrosion Inhibitors beneath the tank floor. The vapors diffuse through the interstitial space and form a protective molecular layer on accessible soil-side steel surfaces.
In some applications, CorroLogic® material can be introduced beneath an existing tank without raising or emptying it. Feasibility depends on the tank, foundation, access, operating conditions, and engineered application design.
CorroLogic® may be used alone in some engineered applications or as a complementary layer with cathodic protection. The appropriate approach depends on tank design, soil-side conditions, existing systems, inspection data, and regulatory requirements.
Yes. Compatible tanks may be protected using VpCI® fogging fluids, powders, emitters, coatings, and sealed layup procedures. Cleaning, contamination, internal volume, closure, shutdown duration, and recommissioning must be considered.
Yes. Cortec® offers inhibitors for compatible hydrotest-water applications. Product selection depends on water chemistry, metallurgy, coatings, test duration, discharge requirements, and final tank service.
Certain Cortec® additives are designed for compatible fuel, petroleum, and lubricating-oil systems. No product should be introduced without confirming compatibility, concentration, approvals, downstream use, filtration, and applicable regulations.
Certain VpCI® products provide vapor-phase protection within enclosed headspace. The inhibitor migrates through the air and forms a protective molecular layer on accessible metal surfaces above the liquid.
Only a product specifically approved for potable-water service should be considered. Current product approvals, water-quality regulations, dosage, system materials, and required flushing procedures must be verified.
Yes. ECORR Systems can help review the tank design, metallurgy, stored product, tank-bottom configuration, water chemistry, corrosion location, operating status, shutdown duration, and application requirements to identify an appropriate Cortec® solution.