Skip to main content
Your Saved For Later list is empty.
My Favorites
Products 28-36 of 36

Filter

Sort By

Cortec VpCI®-639 High Temperature Inhibitor for Oil / Gas / Petrochemical From Ecorrsystems

Cortec VpCI®-639 | High Temperature Inhibitor for Oil / Gas / Petrochemical | 5 Gal

Price: Quote

    Cortec VpCI®-639 | High Temperature Inhibitor for Oil / Gas / Petrochemical | 5 Gal  VpCI®-639 is designed to provide corrosion protection against the severe conditions encountered in petroleum...

    Cortec VpCI®-639 | High Temperature Inhibitor for Oil / Gas / Petrochemical | 5 Gal  VpCI®-639 is designed to provide corrosion protection against the severe conditions encountered in petroleum production and refining. VpCI®-639 is effective for a wide range of refined hydrocarbons, crudes, and oil/water ratios. As a fast acting long-term corrosion inhibitor, VpCI®-639 forms an effective anti-corrosion barrier for metals in the presence of water, halogens, and corrosive gases such as...

    Made to Order
    Cortec VpCI®-639 High Temperature Inhibitor for Oil / Gas / Petrochemical From Ecorrsystems

    Cortec VpCI®-639 | High Temperature Inhibitor for Oil / Gas / Petrochemical | 55 Gal

    Price: Quote

      Cortec VpCI®-639 | High Temperature Inhibitor for Oil / Gas / Petrochemical | 55 Gal  VpCI®-639 is designed to provide corrosion protection against the severe conditions encountered in...

      Cortec VpCI®-639 | High Temperature Inhibitor for Oil / Gas / Petrochemical | 55 Gal  VpCI®-639 is designed to provide corrosion protection against the severe conditions encountered in petroleum production and refining. VpCI®-639 is effective for a wide range of refined hydrocarbons, crudes, and oil/water ratios. As a fast acting long-term corrosion inhibitor, VpCI®-639 forms an effective anti-corrosion barrier for metals in the presence of water, halogens, and corrosive gases such as...

      Made to Order
      Cortec VpCI®-649 Liquid Additive From Ecorrsystems

      Cortec VpCI®-649 | Liquid Additive | 55 Gal

      Price: Quote

        Cortec VpCI®-649 | Liquid Additive | 55 Gal  VpCI®-649 is a unique concentrated liquid formulation that protects ferrous and non-ferrous metals from corrosive solutions. In addition, this...

        Cortec VpCI®-649 | Liquid Additive | 55 Gal  VpCI®-649 is a unique concentrated liquid formulation that protects ferrous and non-ferrous metals from corrosive solutions. In addition, this product is designed to provide long-term protection in fresh water and glycol closed loop systems. VpCI®-649 combines contact and volatile corrosion inhibitors along with anti-scalants in a formulation that does not contain nitrites, phosphates or chromates. This product helps solve the problem of...

        Available
        Cortec VpCI®-649  Liquid Additive From Ecorrsystems

        Cortec VpCI®-649 | Multimetal Liquid Additive | 5 Gal

        Price: $366.00

          Cortec VpCI®-649 | Multimetal Liquid Additive | 5 Gal  VpCI®-649 is a unique concentrated liquid formulation that protects ferrous and non-ferrous metals from corrosive solutions. In addition,...

          Cortec VpCI®-649 | Multimetal Liquid Additive | 5 Gal  VpCI®-649 is a unique concentrated liquid formulation that protects ferrous and non-ferrous metals from corrosive solutions. In addition, this product is designed to provide long-term protection in fresh water and glycol closed loop systems. VpCI®-649 combines contact and volatile corrosion inhibitors along with anti-scalants in a formulation that does not contain nitrites, phosphates or chromates. This product helps solve the problem...

          Available
          Cortec VpCI®-649P Additive From ECORR Systems

          Cortec VpCI®-649P | Additive | 100 Lbs

          Price: Quote

            Cortec VpCI®-649P | Additive | 100 Lbs  VpCI®-649 Powder is a unique powder formulation for protecting different metals against corrosion. It is designed to provide long- term protection in...

            Cortec VpCI®-649P | Additive | 100 Lbs  VpCI®-649 Powder is a unique powder formulation for protecting different metals against corrosion. It is designed to provide long- term protection in open and closed loop cooling systems. VpCI®-649 Powder combines contact and volatile corrosion inhibitors in a biodegradable formulation that does not contain nitrites, phosphates, chromates, or heavy metals. Being environmentally safe, it helps solve the problem of disposal, particularly for large...

            Made to Order
            Cortec VpCI®-649P Additive From ECORR Systems

            Cortec VpCI®-649P | Additive | 5 Lbs

            Price: Quote

              Cortec VpCI®-649P | Additive | 5 lbs VpCI®-649 Powder is a unique powder formulation for protecting different metals against corrosion. It is designed to provide long-term protection in...

              Cortec VpCI®-649P | Additive | 5 lbs VpCI®-649 Powder is a unique powder formulation for protecting different metals against corrosion. It is designed to provide long-term protection in open and closed loop cooling systems. VpCI®-649 Powder combines contact and volatile corrosion inhibitors in a non-toxic, biodegradable formulation that does not contain nitrites, phosphates, chromates or heavy metals. Being environmentally safe, it helps solve the problem of disposal, particularly...

              Made to Order
              Cortec VpCI®-649P Additive From ECORR Systems

              Cortec VpCI®-649P | Additive | 50 Lbs

              Price: Quote

                Cortec VpCI®-649P | Additive | 50 Lbs  VpCI®-649 Powder is a unique powder formulation for protecting different metals against corrosion. It is designed to provide long- term protection in...

                Cortec VpCI®-649P | Additive | 50 Lbs  VpCI®-649 Powder is a unique powder formulation for protecting different metals against corrosion. It is designed to provide long- term protection in open and closed loop cooling systems. VpCI®-649 Powder combines contact and volatile corrosion inhibitors in a biodegradable formulation that does not contain nitrites, phosphates, chromates, or heavy metals. Being environmentally safe, it helps solve the problem of disposal, particularly for large...

                Made to Order
                Cortec VpCI®S-16 Defoamer Anti-foaming agent From Ecorrsystems

                Cortec VpCI®S-16 | Defoamer | Anti-foaming agent | 5 Gal

                Price: Quote

                  Cortec VpCI®S-16 | Defoamer | Anti-foaming agent | 5 Gal Cortec S-16 is an anti-foaming agent designed for application as a tank side defoamer for metalworking fluids or alkaline/acid-based...

                  Cortec VpCI®S-16 | Defoamer | Anti-foaming agent | 5 Gal Cortec S-16 is an anti-foaming agent designed for application as a tank side defoamer for metalworking fluids or alkaline/acid-based cleaners. It may also be incorporated into the neat/concentrate package. S-16 has been specifically formulated for use in conjunction with Cortec VpCI systems. S-16 is water-soluble and will maintain defoaming persistence in different dilutions. S-16 will not haze or separate from the concentrate during...

                  Made to Order
                  Cortec VpCI®S-49 | Fuel Additive |  5 Gal fuel dispersant, emulsifier, fuel emulsifier, vpci, ecorr, cortec, environmentally friendly fuel emulsifier, fuel additive, VCI-S49-5

                  Cortec VpCI®S-49 | Fuel Additive | 5 Gal

                  Price: Quote

                    Cortec VpCI®S-49 | Fuel Additive | 5 Gal VpCI-S49 Fuel Additive 5 Gal. S-49 is a fuel oil dispersant/emulsifier that keeps insoluble particles dispersed, thus reducing carbon deposits on tips, soot...

                    Cortec VpCI®S-49 | Fuel Additive | 5 Gal VpCI-S49 Fuel Additive 5 Gal. S-49 is a fuel oil dispersant/emulsifier that keeps insoluble particles dispersed, thus reducing carbon deposits on tips, soot formations, smoke emissions, particulate emissions and sludge deposits in fuel storage tanks. S-49 is a blend of solvents, dispersants, surfactants and emulsifiers for treatment of fuel oil grades 2, 4, 5 and 6. Cortec is a world leader in rust and corrosion removal and protection. Cortec VpCI®...

                    Made to Order

                    Storage Tank Applications for Cortec® VpCI® Corrosion Control Products

                    ECORR Systems provides Cortec® VpCI® corrosion protection solutions for aboveground storage tanks, tank farms, process vessels, fuel tanks, water tanks, and related equipment. These products help protect internal surfaces, tank-bottom plates, interstitial spaces, piping, valves, and stored components during construction, hydrostatic testing, operation, shutdown, maintenance, and long-term layup.

                    As an Authorized Cortec® Distributor, ECORR Systems offers VpCI® powders, fogging fluids, water-treatment additives, rust removers, cleaners, temporary coatings, packaging products, and engineered CorroLogic® solutions for storage tank corrosion protection.


                    Storage Tank Corrosion Challenges

                    Storage tanks may be exposed to water, condensation, oxygen, chlorides, acidic gases, process chemicals, fuel contaminants, microorganisms, soil conditions, and changing temperatures. Corrosion can develop inside the tank, beneath the floor, between double bottoms, under insulation, or on external surfaces.

                    Because many affected surfaces are hidden or difficult to inspect, corrosion may continue unnoticed until it causes product contamination, wall or floor thinning, leaks, repairs, environmental concerns, or an unplanned shutdown.


                    Cortec® VpCI® Solutions for Storage Tanks

                    Cortec® VpCI® technology uses Vapor phase Corrosion Inhibitors that diffuse through enclosed spaces and form a protective molecular layer on accessible metal surfaces. This vapor-phase action helps protect recessed areas, internal cavities, tank headspace, interstitial spaces, and irregular surfaces that may be difficult to reach with conventional coatings.

                    Depending on the application, Cortec® products may be introduced as powders, liquids, fogging treatments, water additives, slurries, direct-applied coatings, emitters, or corrosion-inhibiting packaging.

                    The proper solution depends on the tank design, stored product, metallurgy, temperature, water content, internal condition, tank-bottom configuration, operating status, and required protection period.


                    Common Storage Tank Applications

                    • Aboveground storage tanks
                    • Single-bottom and double-bottom tanks
                    • Crude oil and petroleum storage tanks
                    • Fuel and aviation-fuel tanks
                    • Diesel and gasoline storage tanks
                    • Lubricating-oil storage tanks
                    • Water and fire-water tanks
                    • Chemical and process storage tanks
                    • Ballast and marine storage tanks
                    • Pressure vessels and process containers
                    • Tank farms and bulk-storage terminals
                    • New tanks awaiting commissioning
                    • Tanks undergoing inspection or repair
                    • Empty tanks placed into temporary shutdown
                    • Long-term tank layup and mothballing

                    Aboveground Storage Tank Bottom Protection

                    The underside of an aboveground storage tank floor is one of the most difficult areas to inspect and protect. Moisture, chlorides, soil conditions, foundation materials, and contaminants can create a corrosive environment beneath the tank.

                    Tank floors may not remain in uniform contact with the underlying pad. Irregularities, settlement, welding distortion, and movement caused by filling and emptying can create small voids where moisture and corrosive contaminants accumulate.

                    CorroLogic® VpCI® systems introduce Vapor phase Corrosion Inhibitors beneath the tank floor. The inhibitors diffuse through the interstitial space and form a protective molecular layer on accessible soil-side steel surfaces, including areas that may not remain in direct contact with the tank pad.


                    CorroLogic® Protection for New and Existing Tanks

                    CorroLogic® can be incorporated into the design and construction of a new aboveground storage tank or installed as part of an existing tank’s corrosion-management program. Available application methods may include CorroLogic® Powder, Slurry, or engineered injection and distribution systems.

                    For some existing tanks, CorroLogic® materials can be introduced beneath the tank floor through properly designed injection points without raising or emptying the tank. Feasibility depends on tank construction, foundation design, access, operating conditions, and applicable facility requirements.

                    CorroLogic® installation should be designed and performed by qualified corrosion professionals and authorized applicators.


                    VpCI® and Cathodic Protection

                    Cathodic protection is commonly used to control soil-side corrosion on aboveground storage tank bottoms. Its effectiveness depends on electrical continuity, system condition, tank-bottom contact, anode performance, current distribution, and monitoring.

                    Vapor phase Corrosion Inhibitors may be used as a complementary layer of protection in areas where contact with the cathodically protected pad is uneven or where voids exist beneath the tank floor. VpCI® technology does not require a continuous electrical power source to establish its protective molecular layer.

                    The relationship between VpCI® treatment and cathodic protection must be evaluated for the specific tank. Neither method eliminates the need for inspection, integrity management, leak detection, or regulatory compliance.


                    Industry Guidance for Tank-Bottom VCI Protection

                    Vapor corrosion inhibitor technology for aboveground storage tank bottoms is addressed by industry guidance, including API Technical Report 655, Vapor Corrosion Inhibitors for Storage Tanks. AMPP SP21474-2023 also addresses external corrosion control for on-grade carbon-steel storage tank bottoms.

                    These documents provide industry context but do not replace tank-specific engineering, regulatory requirements, inspection standards, or the owner’s integrity-management program.


                    Internal Storage Tank Corrosion Protection

                    Internal corrosion may occur when water, oxygen, salts, sludge, acidic contaminants, or process materials contact the tank wall, floor, roof, internal supports, or other components. Corrosion risk may be especially high at the product-water interface and in the headspace above the stored liquid.

                    Cortec® offers product-specific corrosion inhibitors for selected fuel, oil, water, brine, and process applications. Certain formulations can provide protection in the liquid phase, at the liquid-vapor interface, and within the tank headspace.

                    Compatibility with the stored product, tank lining, seals, filtration, downstream process, and applicable regulations must be confirmed before adding any corrosion inhibitor to a storage tank.


                    Tank Headspace and Void-Space Protection

                    Tank headspace can contain humid air and corrosive vapors that condense on the roof, shell, internal supports, and metal surfaces above the liquid level. Contact-only inhibitors in the stored liquid may not reach these areas.

                    Cortec® VpCI® fogging fluids and powders can establish a corrosion-inhibiting atmosphere inside compatible empty tanks, void spaces, and enclosed vessels. The inhibitors migrate through the headspace and protect accessible metal surfaces without requiring direct application to every area.

                    The tank should be sufficiently enclosed to retain the required vapor concentration. Tank volume, internal configuration, ventilation, contamination, temperature, and exposure period must be considered when calculating treatment.


                    Empty Tank Shutdown and Layup

                    A tank that has been emptied for inspection, maintenance, reduced production, or long-term shutdown can corrode rapidly if moisture and contaminants remain inside. Temperature changes may also create condensation after the tank appears dry.

                    A tank-layup program may include:

                    • Removal of product residue, sludge, and contaminants
                    • Cleaning and treatment of existing rust
                    • Drainage or drying as required
                    • Internal fogging with a compatible VpCI® product
                    • Placement of corrosion-inhibiting powder or emitters
                    • Protection of valves, nozzles, flanges, and manways
                    • Sealing openings to retain the protective atmosphere
                    • Periodic inspection and corrosion monitoring
                    • A documented recommissioning procedure

                    Wet Storage Tank Layup

                    Some tanks remain filled with water or another compatible fluid during standby. In these applications, the treatment must protect submerged surfaces, the air-water interface, and exposed metal within the headspace.

                    Cortec® water-treatment products provide options for compatible wet-layup applications. Proper mixing and distribution are important so the inhibitor reaches all areas of the system.

                    Water chemistry, tank metallurgy, existing coatings, temperature, biological activity, retained fluid, discharge requirements, and planned return to service should be evaluated before treatment.


                    Storage Tank Hydrostatic Testing

                    Hydrostatic testing introduces water into new, repaired, or inspected tanks. Even after draining, water can remain along floor irregularities, seams, nozzles, supports, and other difficult-to-dry areas.

                    Cortec® corrosion inhibitors can be added to compatible hydrotest water to help protect ferrous and non-ferrous metals during testing and the period between testing and commissioning. Selected products offer contact and vapor-phase protection.

                    Product selection depends on water quality, chloride content, hardness, metallurgy, existing coatings, test duration, discharge requirements, and the tank’s final service.


                    Construction and Commissioning Delays

                    New tanks may remain exposed for months between fabrication, hydrotesting, coating, inspection, and commissioning. Open nozzles, incomplete roofs, rain, salt air, blowing dust, and temperature changes can expose unprotected metal to corrosion.

                    Temporary protection may include hydrotest additives, internal fogging, VpCI® powder, removable coatings, flange protection, VpCI® packaging, and protective covers. The preservation method should remain compatible with welding, coating, inspection, cleaning, and commissioning requirements.


                    Fuel and Petroleum Storage Tanks

                    Fuel and petroleum tanks can accumulate water through condensation, product contamination, or operational conditions. Water settling at the tank bottom may contribute to corrosion, sludge formation, and microbial activity.

                    Cortec® offers product-specific corrosion inhibitor additives for compatible fuel, petroleum, and oil-storage applications. Some formulations provide contact protection within the stored liquid and vapor-phase protection above the fluid level.

                    Fuel specification, downstream equipment, combustion performance, filtration, seals, coatings, regulatory requirements, and additive approvals must be reviewed before treatment.


                    Water and Fire-Water Storage Tanks

                    Water-storage and fire-water tanks may remain filled for extended periods. Dissolved oxygen, chlorides, changing water levels, and microbiological activity can contribute to internal corrosion.

                    Cortec® offers inhibitors for selected industrial-water and fire-water systems. Potable-water tanks require products specifically approved for that use and must comply with all applicable health, water-quality, and facility requirements.


                    Double-Bottom and Interstitial Space Protection

                    Double-bottom storage tanks contain an enclosed space between the original floor and the replacement or secondary floor. Moisture entering this space may create corrosion on surfaces that are difficult to inspect or coat.

                    Vapor phase Corrosion Inhibitors can be introduced into the interstitial space to establish a protective environment. Distribution, sealing, drainage, monitoring points, leak-detection systems, and compatibility with the tank design should be evaluated before application.


                    Tank Roof, Shell, and External Surface Protection

                    External tank surfaces are exposed to rain, humidity, sunlight, salt spray, industrial pollutants, and changing temperatures. Roof plates, stairways, handrails, nozzles, fasteners, supports, and other components may require additional corrosion protection during construction or maintenance.

                    Cortec® offers temporary and longer-term coatings for compatible exterior metal surfaces. Product selection depends on substrate preparation, exposure, ultraviolet resistance, film thickness, appearance, temperature, and required service life.

                    Temporary coatings should not automatically be considered replacements for permanent tank-coating systems.


                    Valve, Flange, Nozzle, and Manway Protection

                    Tank valves, flanges, nozzles, manways, bolts, and gaskets may be exposed during fabrication, shutdown, or maintenance. Machined flange faces are particularly vulnerable because corrosion or pitting can interfere with proper sealing.

                    Cortec® removable coatings, lubricants, VpCI® films, papers, covers, and protective caps can help preserve these components. Compatibility with gasket materials, stored products, operating temperature, and recommissioning procedures should be confirmed.


                    Storage Tank Cleaning and Rust Removal

                    Product residue, sludge, oil, grease, salts, rust, and scale may need to be removed before inspection, repair, coating, or preservation. Cleaning requirements depend on the previous tank contents and the work being performed.

                    Cortec® offers industrial cleaners, degreasers, rust removers, and scale-removal products for compatible metals and tank applications. Some cleaners contain corrosion inhibitors to help reduce flash rust after cleaning.

                    Tank entry, cleaning, ventilation, waste handling, confined-space procedures, and atmospheric testing must be performed according to applicable facility and regulatory requirements.


                    Temporary Coatings and Rust Preventatives

                    Temporary coatings can protect tank components during fabrication, shipment, outdoor staging, maintenance, and shutdown. Cortec® offers water-based, solvent-based, wax-like, removable, oily, and dry-film rust preventatives for different environments.

                    Products such as VpCI®-368 provide removable protection for harsh outdoor conditions, while VpCI®-391 provides a water-based, dry, non-tacky protective film for compatible metal surfaces.


                    Storage Tank Parts and Spares Preservation

                    Tank farms and industrial facilities may keep valves, pumps, seals, gauges, instrumentation, fasteners, and other critical parts in storage. These components must remain protected and ready for maintenance or emergency use.

                    A preservation program may combine cleaning, rust preventatives, corrosion-inhibiting lubricants, VpCI® films, bags, papers, emitters, foams, and protective caps. Stored items should be labeled with the treatment date, product used, inspection schedule, and removal requirements.


                    Cortec® Product Categories for Storage Tanks

                    » Tank, Fuel, Oil, and Water Corrosion Inhibitors
                    For compatible storage fluids, hydrostatic testing, wet layup, fuels, oils, industrial water, and internal tank-preservation applications.

                    » Tank Coatings and Rust Preventatives
                    For compatible tank components, flange faces, nozzles, manways, valves, external surfaces, and equipment exposed during construction or storage.

                    » Industrial Cleaners and Rust Removers
                    For removing compatible oils, grease, residue, rust, scale, and contamination before inspection, coating, repair, or preservation.

                    » Corrosion-Inhibiting Lubricants and Greases
                    For compatible valves, fasteners, hinges, actuators, pumps, bearings, and tank-maintenance equipment.

                    » Tank Layup and VpCI® Packaging Products
                    For empty tank interiors, enclosed voids, valves, replacement parts, maintenance equipment, storage, and shipment.


                    Benefits for Tank Owners and Operators

                    • Protects internal and external tank surfaces
                    • Provides options for soil-side tank-bottom protection
                    • Reaches inaccessible voids and interstitial spaces
                    • Supports tank construction and commissioning delays
                    • Protects tanks during hydrostatic testing
                    • Provides wet and dry layup options
                    • Protects headspace above compatible stored fluids
                    • Supports preservation of valves, flanges, and spare parts
                    • Can complement cathodic protection in engineered applications
                    • Helps reduce corrosion-related repairs, leaks, and downtime

                    Developing a Storage Tank Corrosion-Control Plan

                    A storage tank corrosion-control plan should begin with the tank design, metallurgy, service history, stored product, inspection results, foundation, existing coatings, cathodic protection, and environmental conditions.

                    Important considerations include:

                    • Single-bottom or double-bottom construction
                    • Tank floor and foundation condition
                    • Internal lining and external coating systems
                    • Stored product and possible contaminants
                    • Water accumulation and drainage
                    • Tank operating temperature and pressure
                    • Cathodic protection and leak-detection systems
                    • Tank cleaning and confined-space requirements
                    • Application, distribution, and monitoring methods
                    • Inspection and recommissioning procedures

                    Why Choose ECORR Systems?

                    ECORR Systems is an Authorized Cortec® Distributor helping tank owners, terminal operators, industrial facilities, engineers, contractors, maintenance teams, and corrosion professionals identify appropriate storage tank corrosion-control products.

                    Whether you need a hydrotest additive, internal fogging product, tank-bottom corrosion solution, removable coating, cleaner, rust remover, lubricant, or VpCI® packaging for tank components, ECORR Systems can help evaluate the tank, metallurgy, stored product, exposure conditions, application method, and required protection period.


                    Frequently Asked Questions

                    Where can corrosion occur on a storage tank?

                    Corrosion may develop on internal walls and floors, in the headspace, beneath the exterior tank bottom, between double bottoms, under insulation, on the roof and shell, or on valves, flanges, nozzles, and related components.

                    How does VpCI® protect the underside of an aboveground tank?

                    CorroLogic® products release Vapor phase Corrosion Inhibitors beneath the tank floor. The vapors diffuse through the interstitial space and form a protective molecular layer on accessible soil-side steel surfaces.

                    Can CorroLogic® be installed on an existing tank?

                    In some applications, CorroLogic® material can be introduced beneath an existing tank without raising or emptying it. Feasibility depends on the tank, foundation, access, operating conditions, and engineered application design.

                    Does CorroLogic® replace cathodic protection?

                    CorroLogic® may be used alone in some engineered applications or as a complementary layer with cathodic protection. The appropriate approach depends on tank design, soil-side conditions, existing systems, inspection data, and regulatory requirements.

                    Can Cortec® products protect an empty tank during shutdown?

                    Yes. Compatible tanks may be protected using VpCI® fogging fluids, powders, emitters, coatings, and sealed layup procedures. Cleaning, contamination, internal volume, closure, shutdown duration, and recommissioning must be considered.

                    Can Cortec® products protect tanks during hydrostatic testing?

                    Yes. Cortec® offers inhibitors for compatible hydrotest-water applications. Product selection depends on water chemistry, metallurgy, coatings, test duration, discharge requirements, and final tank service.

                    Can Cortec® products be added directly to stored fuel or oil?

                    Certain Cortec® additives are designed for compatible fuel, petroleum, and lubricating-oil systems. No product should be introduced without confirming compatibility, concentration, approvals, downstream use, filtration, and applicable regulations.

                    Can VpCI® protect tank surfaces above the liquid level?

                    Certain VpCI® products provide vapor-phase protection within enclosed headspace. The inhibitor migrates through the air and forms a protective molecular layer on accessible metal surfaces above the liquid.

                    Can Cortec® products be used in potable-water tanks?

                    Only a product specifically approved for potable-water service should be considered. Current product approvals, water-quality regulations, dosage, system materials, and required flushing procedures must be verified.

                    Can ECORR Systems help select the right storage tank product?

                    Yes. ECORR Systems can help review the tank design, metallurgy, stored product, tank-bottom configuration, water chemistry, corrosion location, operating status, shutdown duration, and application requirements to identify an appropriate Cortec® solution.

                    Protect Storage Tanks with Cortec® VpCI® Solutions

                    ECORR Systems helps tank owners and industrial facilities identify Cortec® corrosion inhibitors, tank-bottom solutions, hydrotest additives, coatings, cleaners, and layup products for storage tanks and related equipment.