Skip to main content
Your Saved For Later list is empty.
My Favorites
Products 64-67 of 67

Filter

Sort By

Cortec® VpCI® M-640 | Powder Additive for Engine Coolants from ECORR Systems

Cortec® VpCI® M-640 | Powder Additive for Engine Coolants | 100 lbs

Price: Quote

    Cortec VpCI®M-640 Powder | Additive for Engine Coolants | 100 lbs (CUSTOM PRODUCT) M-640 is a corrosion inhibiting additive for water and glycol-based heat exchange fluids. It...

    Cortec VpCI®M-640 Powder | Additive for Engine Coolants | 100 lbs (CUSTOM PRODUCT) M-640 is a corrosion inhibiting additive for water and glycol-based heat exchange fluids. It protects ferrous and non-ferrous metals from corrosive contaminants. This product is an excellent replacement for phosphate/nitrite-based/amine compounds. M-640 is based on an organic- inorganic formulation designed for low level concentrations in field applications. M-640 contains a unique combination of...

    Made to Order
    Cortec® VpCI® M-640 | Powder Additive for Engine Coolants from ECORR Systems

    Cortec® VpCI® M-640 | Powder Additive for Engine Coolants | 5 lb

    Price: Quote

      Cortec VpCI® M640 Powder | Additive for Engine Coolants | 5 lb  M-640 is a corrosion inhibiting additive for water and glycol-based heat exchange fluids. It protects ferrous and...

      Cortec VpCI® M640 Powder | Additive for Engine Coolants | 5 lb  M-640 is a corrosion inhibiting additive for water and glycol-based heat exchange fluids. It protects ferrous and non-ferrous metals from corrosive contaminants. This product is an excellent replacement for phosphate/nitrite-based/amine compounds. M-640 is based on an organic- inorganic formulation designed for low level concentrations in field applications. M-640 contains a unique combination of contact and vapor phase...

      Made to Order
      Cortec® VpCI® M-640 | Powder Additive for Engine Coolants from ECORR Systems

      Cortec® VpCI® M-640 | Powder Additive for Engine Coolants | 50 lb

      Price: Quote

        Cortec VpCI®M-640 Powder | Additive for Engine Coolants | 50 lb  M-640 is a corrosion inhibiting additive for water and glycol-based heat exchange fluids. It protects ferrous and...

        Cortec VpCI®M-640 Powder | Additive for Engine Coolants | 50 lb  M-640 is a corrosion inhibiting additive for water and glycol-based heat exchange fluids. It protects ferrous and non-ferrous metals from corrosive contaminants. This product is an excellent replacement for phosphate/nitrite-based/amine compounds. M-640 is based on an organic- inorganic formulation designed for low level concentrations in field applications. M-640 contains a unique combination of contact and vapor...

        Made to Order
        Cortec® VpCI® M-640L | Liquid Additive for Engine Coolants from ECORR Systems

        Cortec® VpCI® M-640L | Liquid Additive for Engine Coolants | 55 Gal

        Price: Quote

          Cortec VpCI®M640L | Additive for Engine Coolants | 55 Gal  M-640 L is a liquid corrosion inhibiting additive for water and glycol-based heat exchange fluids.It protects ferrous and...

          Cortec VpCI®M640L | Additive for Engine Coolants | 55 Gal  M-640 L is a liquid corrosion inhibiting additive for water and glycol-based heat exchange fluids.It protects ferrous and non-ferrous metals from corrosive contaminants. This product is an excellent replacement for silicates and phosphate/nitrite- based/amine compounds. M-640 L is based on an organic-inorganic formulation designed for low level concentrations in field applications. M-640 L contains a unique combination of...

          Available

          Cortec® VpCI® Water and Oil Corrosion Inhibitor Additives

          ECORR Systems provides Cortec® VpCI® water and oil additives for industrial systems, process equipment, hydraulic systems, circulating oils, closed loops, hydrostatic testing, equipment preservation, and other applications where internal metal surfaces require corrosion protection.

          As an Authorized Cortec® Distributor, ECORR Systems helps maintenance teams, manufacturers, equipment operators, and industrial facilities select corrosion-inhibiting additives based on the carrier fluid, metal types, operating conditions, required concentration, and intended protection period.


          Corrosion Protection Inside Fluid Systems

          Water, condensation, dissolved oxygen, salts, acidic byproducts, contamination, and changing operating temperatures can cause corrosion inside tanks, piping, pumps, valves, heat exchangers, hydraulic systems, gearboxes, engines, and process equipment.

          Cortec® additives introduce corrosion-inhibiting chemistry directly into compatible water-, oil-, fuel-, glycol-, or process-fluid systems. Selected products provide protection in the liquid phase and may also protect metal surfaces above the fluid level through Vapor phase Corrosion Inhibitor action.


          Common Applications

          • Closed-loop water systems
          • Freshwater and glycol systems
          • Hydrostatic testing water
          • Cooling and heat-transfer loops
          • Hydraulic systems and hydraulic fluids
          • Gearboxes and circulating lubrication systems
          • Engines, transmissions, pumps, and compressors
          • Storage tanks, vessels, piping, and valves
          • Saltwater, seawater, and brine systems
          • Fuel and fuel-oil systems
          • Equipment commissioning and startup
          • Seasonal shutdown and temporary layup
          • Equipment storage and overseas shipment
          • Intermittently operated machinery

          Types of Water and Oil Additives

          Water-Based Corrosion Inhibitor Additives

          Water-compatible additives protect metal surfaces contacted by treated water. Selected products may be used in closed loops, hydrostatic testing, process water, equipment preservation, or temporary layup.

          Oil and Lubricant Additives

          Oil-compatible corrosion inhibitors can be blended into approved mineral oils, synthetic oils, lubricants, hydraulic fluids, circulating oils, or preservation oils. These additives help protect internal components during operation, intermittent use, shutdown, and storage.

          Closed-Loop and Glycol Additives

          Selected formulations provide multi-metal protection in compatible freshwater and glycol closed-loop systems. System metallurgy, glycol type, concentration, water chemistry, and operating temperature must be considered.

          Hydrostatic Testing Additives

          Hydrotest additives help protect internal metal surfaces while equipment, tanks, piping, valves, and vessels are filled with test water. Selected products may also protect residual moisture and enclosed vapor spaces after draining.

          Saltwater and Brine Additives

          Specialized additives protect compatible equipment exposed to seawater, brine, chlorides, and other corrosive salt solutions. These applications require careful review of water chemistry, concentration, metallurgy, and exposure time.

          Fuel and Fuel-Oil Additives

          Selected Cortec® additives are formulated for compatible gasoline, diesel, fuel-oil, alcohol-fuel, or storage applications. Fuel type, equipment requirements, treatment concentration, and manufacturer recommendations must be reviewed before use.

          Layup and Preservation Additives

          Preservation additives protect equipment during seasonal shutdown, standby service, shipment, construction delays, or long-term storage. Some products can remain in the system for startup, while others may require draining, flushing, or replacement.


          Featured Cortec® Additive Technologies

          » M-529 Oil and Lubricant Additive
          An oil-based corrosion-inhibitor package for compatible mineral and synthetic lubricating oils used during normal operation, intermittent operation, and equipment storage.

          » VpCI®-649
          A concentrated formulation combining contact and vapor-phase corrosion inhibitors with antiscalant properties for compatible freshwater and glycol closed-loop systems.

          » VpCI®-644
          A corrosion-inhibiting additive for ferrous and non-ferrous metals in compatible water systems containing inorganic salts, including chlorides.

          » VpCI®-645 Marine Corrosion Inhibitor
          A concentrated inhibitor for compatible freshwater, saltwater, brine, and other corrosive water environments containing halogens or dissolved sulfides.

          » M-645 Saltwater and Brine Additive
          A surface-active corrosion-inhibitor concentrate designed to displace chloride-containing water and form an oily protective film on compatible metal surfaces.

          » VpCI®-705 Fuel Additive
          A corrosion-preventive additive for approved gasoline, diesel, gasohol, alcohol-fuel, and fuel-storage applications.


          Liquid, Vapor, and Interface Protection

          A partially filled system can develop different corrosion zones:

          • Liquid phase: Metal continuously contacted by water, oil, fuel, or process fluid.
          • Vapor phase: Metal located above the fluid level in an enclosed system.
          • Liquid-vapor interface: Metal near a changing fluid level, where oxygen and moisture may create aggressive corrosion conditions.

          Selected Cortec® VpCI® additives are formulated to protect more than one of these areas. The system must remain sufficiently enclosed for vapor-phase protection to develop and remain effective.


          Operating Systems vs. Equipment Layup

          An additive intended for normal operation may have different performance and compatibility requirements than a product used only during storage.

          • Operating systems require compatibility with temperature, pressure, seals, filtration, lubrication requirements, and existing treatment chemistry.
          • Intermittent systems may require protection during repeated startup and shutdown cycles.
          • Wet layup keeps the system filled with treated fluid during shutdown.
          • Dry layup may use treated water during preparation followed by draining, drying, and vapor-phase preservation.
          • Shipping and storage may require temporary treatment that can remain in place or be removed before commissioning.

          Oil-System Compatibility

          Before adding a corrosion inhibitor to an oil-based system, confirm compatibility with:

          • Mineral, synthetic, or biobased base oil
          • Oil viscosity and viscosity index
          • Existing antiwear and extreme-pressure additives
          • Antioxidants, detergents, and dispersants
          • Seals, gaskets, hoses, and elastomers
          • Bearings, gears, pumps, and hydraulic components
          • Filtration and water-separation requirements
          • Operating temperature and pressure
          • Original equipment manufacturer specifications

          Do not introduce an additive into an in-service lubricant solely on the basis of general oil compatibility. Review the complete fluid formulation and equipment requirements.


          Water-System Compatibility

          Water chemistry can significantly affect inhibitor performance. Important factors include:

          • pH and alkalinity
          • Hardness and dissolved minerals
          • Chloride and sulfate concentration
          • Dissolved oxygen
          • Conductivity and total dissolved solids
          • Glycol type and concentration
          • Existing biocides, antiscalants, and treatment chemicals
          • System temperature and circulation rate
          • Ferrous and non-ferrous metals present
          • Makeup-water and discharge requirements

          Hydrostatic Testing and Residual Water

          Hydrostatic testing can introduce moisture, oxygen, salts, and contaminants into newly fabricated or existing equipment. Corrosion may begin during the test or after draining if water remains trapped in low points, crevices, valves, and dead legs.

          A properly selected additive can protect metal during the test and may help protect residual moisture after draining. The additive must be compatible with the system metallurgy, test-water chemistry, discharge requirements, and equipment commissioning plan.


          Determining Treatment Concentration

          Additive concentration should be based on the current technical data sheet and the specific operating conditions. Required dosage may depend on:

          • Total system volume
          • Carrier-fluid type
          • Water or oil chemistry
          • Metal types and surface condition
          • Temperature and pressure
          • Contaminant and chloride levels
          • Operating or preservation period
          • System turnover, leakage, and makeup fluid
          • Existing treatment chemicals
          • Required vapor-space protection

          Under-treatment may provide inadequate protection, while excessive treatment can affect cost, residue, foaming, fluid performance, or downstream processes.


          Mixing and Adding Corrosion Inhibitors

          Depending on the product, an additive may be introduced into a tank, reservoir, circulating loop, blending vessel, test-water supply, or base fluid before filling.

          For consistent treatment:

          • Calculate the actual system or fluid volume.
          • Confirm the recommended treatment concentration.
          • Follow the specified order of addition.
          • Provide sufficient agitation or circulation for uniform distribution.
          • Avoid mixing concentrated chemicals directly unless approved.
          • Verify pH, concentration, or other control values when required.
          • Document the product, batch, quantity, and treatment date.

          Testing Before Full-Scale Treatment

          Laboratory or small-scale compatibility testing is recommended before adding a new product to an operating system. Testing may evaluate:

          • Corrosion protection
          • Fluid stability and separation
          • Foaming and air release
          • Viscosity and lubricity
          • Filterability
          • Seal and elastomer compatibility
          • Scale and deposit formation
          • Interaction with existing additives
          • Surface residue and cleanliness
          • Downstream process compatibility

          Benefits of Cortec® Water and Oil Additives

          • Internal corrosion protection for fluid-containing systems
          • Options for water, oil, glycol, fuel, saltwater, and brine
          • Products for operating equipment and temporary preservation
          • Protection for ferrous and selected non-ferrous metals
          • Selected liquid-, vapor-, and interface-phase protection
          • Concentrated formulations for controlled dosing
          • Protection during hydrotesting, shutdown, storage, and shipment
          • Reduced rust deposits and corrosion-related contamination
          • Protection for enclosed and difficult-to-reach internal surfaces
          • Reduced risk of leakage, component damage, and premature maintenance

          Safety, Handling, and System Approval

          Review the current technical data sheet and safety data sheet before handling or adding any corrosion inhibitor. Confirm required personal protective equipment, ventilation, storage conditions, dilution, mixing, disposal, and spill-response procedures.

          Obtain appropriate engineering, process, or original equipment manufacturer approval before treating critical operating equipment. Product suitability is application-specific and should not be assumed from general water or oil compatibility.


          Related Cortec® Product Categories

          » Coating and Fluid Additives
          Corrosion-inhibiting additives for compatible coatings, process fluids, water-treatment formulations, and industrial systems.

          » Enhanced Lubricants
          Finished lubricants formulated to reduce friction, wear, and corrosion in machinery and equipment.

          » Water Treatment
          Corrosion-control solutions for boilers, cooling water, closed loops, process water, and industrial treatment programs.

          » VpCI® Powders
          Water-soluble and dry-applied corrosion inhibitors for internal spaces, hydrotesting, preservation, and equipment layup.

          » Cleaners and Degreasers
          Products for cleaning tanks, components, equipment, and fluid systems before treatment or preservation.


          Why Choose ECORR Systems?

          ECORR Systems is an Authorized Cortec® Distributor helping industrial facilities, equipment manufacturers, maintenance teams, water-treatment professionals, and system operators select corrosion-inhibitor additives for fluid systems and equipment preservation.

          ECORR Systems can help evaluate the carrier fluid, water chemistry, base oil, system metallurgy, operating temperature, treatment objective, concentration, and required protection period to identify an appropriate Cortec® additive.


          Frequently Asked Questions

          What is a corrosion-inhibitor additive?

          A corrosion-inhibitor additive is a concentrated product introduced into a compatible water, oil, fuel, glycol, or process fluid to help protect metal surfaces contacted by that fluid.

          Can one additive be used in both water and oil?

          Usually not. Water-soluble and oil-soluble additives have different chemistries and compatibility requirements. Select a product specifically designed for the carrier fluid and application.

          Can Cortec® additives protect metal above the fluid level?

          Selected VpCI® additives provide vapor-phase protection to metal above the fluid level in sufficiently enclosed systems. This capability is product-specific and should be verified before use.

          Can an additive be used in an operating gearbox or hydraulic system?

          Certain oil-compatible additives are designed for operating or intermittently operated equipment. Compatibility with the existing oil, additive package, seals, filters, equipment specifications, and operating conditions must be confirmed.

          Are Cortec® additives suitable for hydrostatic testing?

          Selected Cortec® products are formulated for hydrotesting and post-test preservation. Product selection depends on the metals, water chemistry, test duration, discharge requirements, and commissioning process.

          How much additive should be used?

          Dosage depends on the product, fluid volume, chemistry, contamination, temperature, metal types, and protection objective. Follow the current technical data sheet or a project-specific recommendation.

          Can different corrosion inhibitors be mixed?

          Do not mix additives unless compatibility has been confirmed. Incompatible chemistries may cause precipitation, separation, foaming, deposits, or reduced corrosion protection.

          Does the treated fluid need to be removed before startup?

          This depends on the product and equipment. Some additives can remain in the operating fluid, while preservation treatments may require draining, flushing, or replacement before commissioning.

          Can ECORR Systems recommend a treatment concentration?

          Yes. ECORR Systems can review the system volume, carrier fluid, water chemistry, metallurgy, operating conditions, and protection period to help identify an appropriate product and starting concentration.

          Protect Internal Metal Surfaces with Cortec® Additives

          ECORR Systems can help you select the right water-, oil-, glycol-, fuel-, or brine-compatible corrosion inhibitor for operating systems, hydrotesting, shutdown, storage, and equipment preservation.