Skip to main content
Your Saved For Later list is empty.
My Favorites
Products 19-27 of 67

Filter

Sort By

Cortec VpCI®-344 Metalworking Water-borne Coolant / Lubricant From Ecorrsystems

Cortec VpCI®-344 | Metalworking Water-borne Coolant / Lubricant | 5 Gal

Price: Quote

    Cortec VpCI®-344 | Metalworking Water-borne Coolant / Lubricant | 5 Gal NOTE: Minimum Order Quantity (10) pails VpCI®-344 is a concentrated corrosion preventive liquid/ metalworking...

    Cortec VpCI®-344 | Metalworking Water-borne Coolant / Lubricant | 5 Gal NOTE: Minimum Order Quantity (10) pails VpCI®-344 is a concentrated corrosion preventive liquid/ metalworking lubricant for wet tempering of galvanized and cold-rolled steel, difficult-to-produce metal stampings, wire rope, tubular products and machine parts. This water-based product utilizes Vapor phase Corrosion Inhibitor (VpCI) technology for maximum protection. VpCI®-344 gives very good protection when coated...

    Made to Order
    Cortec VpCI®-344 Metalworking Water-borne Coolant / Lubricant From Ecorrsystems

    Cortec VpCI®-344 | Metalworking Water-borne Coolant / Lubricant | 55 Gal

    Price: Quote

      Cortec VpCI®-344 | Metalworking Water-borne Coolant / Lubricant | 55 Gal  VpCI®-344 is a concentrated corrosion preventive liquid/ metalworking lubricant for wet tempering of galvanized and...

      Cortec VpCI®-344 | Metalworking Water-borne Coolant / Lubricant | 55 Gal  VpCI®-344 is a concentrated corrosion preventive liquid/ metalworking lubricant for wet tempering of galvanized and cold-rolled steel, difficult-to-produce metal stampings, wire rope, tubular products and machine parts. This water-based product utilizes Vapor phase Corrosion Inhibitor (VpCI) technology for maximum protection. VpCI®-344 gives very good protection when coated on metal surfaces, and has a unique vapor...

      Made to Order
      Cortec VpCI®-369 High Performance Oil-Based Coating From Ecorrsystems

      Cortec VpCI®-369 | High Performance Oil-Based Coating | 5 Gal

      Price: $374.00

        Cortec VpCI®-369 | High Performance Oil-Based Coating | 5 Gal  VpCI®-369 is our best corrosion inhibitor for use as an oil additive and/ or temporary coating. The protective film is...

        Cortec VpCI®-369 | High Performance Oil-Based Coating | 5 Gal  VpCI®-369 is our best corrosion inhibitor for use as an oil additive and/ or temporary coating. The protective film is self-healing and moisture-displacing, providing superior protection against aggressive environments. VpCI®-369 is also excellent when used as an oil additive for mothballing, shipping or storage of parts and equipment. In small percentages, VpCI®-369 has a minimal effect on viscosities. Meets MIL-PRF-16173E...

        Available
        Cortec VpCI®-369 High Performance Oil-Based Coating From Ecorrsystems

        Cortec VpCI®-369 | High Performance Oil-Based Coating | 55 Gal

        Price: Quote

          Cortec VpCI®-369 | High Performance Oil-Based Coating | 55 Gal  VpCI®-369 is our best inhibitor for use as an oil additive and/ or temporary coating. The protective film is self-healing and...

          Cortec VpCI®-369 | High Performance Oil-Based Coating | 55 Gal  VpCI®-369 is our best inhibitor for use as an oil additive and/ or temporary coating. The protective film is self-healing and moisture-displacing, providing superior protection against aggressive environments. VpCI®-369 is also excellent when used as an oil additive for mothballing, shipping or storage of parts and equipment. In small percentages, VpCI®-369 has a minimal effect on viscosities. Meets MIL-PRF-16173E (Grade 2)....

          Available
          Cortec VpCI®-369D High Performance Oil-Based Coating From Ecorrsystems

          Cortec VpCI®-369D | High Performance Oil-Based Coating | 5 Gal

          Price: $304.00

            Cortec VpCI®-369D | High Performance Oil-Based Coating | 5 Gal  VpCI®-369D is the diluted, ready-to-use version of VpCI®-369. It provides the same excellent performance of regular VpCI®-369...

            Cortec VpCI®-369D | High Performance Oil-Based Coating | 5 Gal  VpCI®-369D is the diluted, ready-to-use version of VpCI®-369. It provides the same excellent performance of regular VpCI®-369 without any diluting required. VpCI®-369D is a lubricating coating that leaves an oily film, which provides excellent outdoor protection. The film is self-healing and moisture-displacing. Cortec is a world leader in rust and corrosion removal and protection. Cortec VpCI® products offer cost-effective...

            Available
            Cortec VpCI®-369D High Performance Oil-Based Coating From Ecorrsystems

            Cortec VpCI®-369D | High Performance Oil-Based Coating | 55 Gal

            Price: Quote

              Cortec VpCI®-369D | High Performance Oil-Based Coating | 55 Gal  VpCI®-369D is the diluted, ready-to-use version of VpCI®-369. It provides the same excellent performance of regular VpCI®-369...

              Cortec VpCI®-369D | High Performance Oil-Based Coating | 55 Gal  VpCI®-369D is the diluted, ready-to-use version of VpCI®-369. It provides the same excellent performance of regular VpCI®-369 without any diluting required. VpCI®-369 D is an oil-based temporary coating that provides protection in harsh, outdoor, sheltered applications. Provides multi-metal protection. Excellent lubricity. Can be matched to some custom colors. NSN 8030-00-244-1295, 244- 1297, 244-1298, 01-149-1731 UFI:...

              Available
              Cortec VpCI®-369M High Performance Oil-Based Coating From Ecorrsytems

              Cortec VpCI®-369M | High Performance Oil-Based Coating | 5 Gal

              Price: Quote

                Cortec VpCI®-369M | High Performance Oil-Based Coating | 5 Gal  VpCI®-369M is an oil-based temporary coating that provides protection in harsh, outdoor, sheltered applications. Provides...

                Cortec VpCI®-369M | High Performance Oil-Based Coating | 5 Gal  VpCI®-369M is an oil-based temporary coating that provides protection in harsh, outdoor, sheltered applications. Provides multi-metal protection. Excellent lubricity. Can be matched to some custom colors. Conforms to MIL – PRF – 16173E (Grade 2), NSN 8030-00-244- 1295, 244-1297, 244-1298, 01- 149-1731. NOTE:  MINIMUM ORDER (10) PAILS - MADE TO ORDERCortec is a world leader in rust and corrosion removal and...

                Made to Order
                Cortec VpCI®-377  Water- Based Rust Preventative From Ecorrsystems

                Cortec VpCI®-377 | Water- Based Rust Preventative | 5 Gal

                Price: $284.00

                  Cortec VpCI®-377 | Water- Based Rust Preventative | 5 Gal  VpCI®-377 is a water-based concentrate designed as a complete replacement for oil-based preventives for indoor protection of...

                  Cortec VpCI®-377 | Water- Based Rust Preventative | 5 Gal  VpCI®-377 is a water-based concentrate designed as a complete replacement for oil-based preventives for indoor protection of equipment and components. VpCI®-377 is a corrosion preventive liquid that meets tough antipollution requirements. The wide dilution range with water (0.5-20 percent) allows flexibility to customize the length of protection required and the applied cost per square foot (or m2). VpCI®-377 forms a solution...

                  Available
                  Cortec VpCI®-377  Water- Based Rust Preventative From Ecorrsystems

                  Cortec VpCI®-377 | Water-Based Rust Preventative | 55 Gal

                  Price: Quote

                    Cortec VpCI®-377 | Water-Based Rust Preventative | 55 Gal  VpCI®-377 is a water-based concentrate designed as a complete replacement for oil-based preventives for indoor protection of equipment...

                    Cortec VpCI®-377 | Water-Based Rust Preventative | 55 Gal  VpCI®-377 is a water-based concentrate designed as a complete replacement for oil-based preventives for indoor protection of equipment and components. VpCI®-377 is a corrosion preventive liquid that meets tough antipollution requirements. The wide dilution range with water (0.5-20 percent) allows flexibility to customize the length of protection required and the applied cost per square foot (or m2). VpCI®-377 forms a solution in...

                    Available

                    Cortec® VpCI® Water and Oil Corrosion Inhibitor Additives

                    ECORR Systems provides Cortec® VpCI® water and oil additives for industrial systems, process equipment, hydraulic systems, circulating oils, closed loops, hydrostatic testing, equipment preservation, and other applications where internal metal surfaces require corrosion protection.

                    As an Authorized Cortec® Distributor, ECORR Systems helps maintenance teams, manufacturers, equipment operators, and industrial facilities select corrosion-inhibiting additives based on the carrier fluid, metal types, operating conditions, required concentration, and intended protection period.


                    Corrosion Protection Inside Fluid Systems

                    Water, condensation, dissolved oxygen, salts, acidic byproducts, contamination, and changing operating temperatures can cause corrosion inside tanks, piping, pumps, valves, heat exchangers, hydraulic systems, gearboxes, engines, and process equipment.

                    Cortec® additives introduce corrosion-inhibiting chemistry directly into compatible water-, oil-, fuel-, glycol-, or process-fluid systems. Selected products provide protection in the liquid phase and may also protect metal surfaces above the fluid level through Vapor phase Corrosion Inhibitor action.


                    Common Applications

                    • Closed-loop water systems
                    • Freshwater and glycol systems
                    • Hydrostatic testing water
                    • Cooling and heat-transfer loops
                    • Hydraulic systems and hydraulic fluids
                    • Gearboxes and circulating lubrication systems
                    • Engines, transmissions, pumps, and compressors
                    • Storage tanks, vessels, piping, and valves
                    • Saltwater, seawater, and brine systems
                    • Fuel and fuel-oil systems
                    • Equipment commissioning and startup
                    • Seasonal shutdown and temporary layup
                    • Equipment storage and overseas shipment
                    • Intermittently operated machinery

                    Types of Water and Oil Additives

                    Water-Based Corrosion Inhibitor Additives

                    Water-compatible additives protect metal surfaces contacted by treated water. Selected products may be used in closed loops, hydrostatic testing, process water, equipment preservation, or temporary layup.

                    Oil and Lubricant Additives

                    Oil-compatible corrosion inhibitors can be blended into approved mineral oils, synthetic oils, lubricants, hydraulic fluids, circulating oils, or preservation oils. These additives help protect internal components during operation, intermittent use, shutdown, and storage.

                    Closed-Loop and Glycol Additives

                    Selected formulations provide multi-metal protection in compatible freshwater and glycol closed-loop systems. System metallurgy, glycol type, concentration, water chemistry, and operating temperature must be considered.

                    Hydrostatic Testing Additives

                    Hydrotest additives help protect internal metal surfaces while equipment, tanks, piping, valves, and vessels are filled with test water. Selected products may also protect residual moisture and enclosed vapor spaces after draining.

                    Saltwater and Brine Additives

                    Specialized additives protect compatible equipment exposed to seawater, brine, chlorides, and other corrosive salt solutions. These applications require careful review of water chemistry, concentration, metallurgy, and exposure time.

                    Fuel and Fuel-Oil Additives

                    Selected Cortec® additives are formulated for compatible gasoline, diesel, fuel-oil, alcohol-fuel, or storage applications. Fuel type, equipment requirements, treatment concentration, and manufacturer recommendations must be reviewed before use.

                    Layup and Preservation Additives

                    Preservation additives protect equipment during seasonal shutdown, standby service, shipment, construction delays, or long-term storage. Some products can remain in the system for startup, while others may require draining, flushing, or replacement.


                    Featured Cortec® Additive Technologies

                    » M-529 Oil and Lubricant Additive
                    An oil-based corrosion-inhibitor package for compatible mineral and synthetic lubricating oils used during normal operation, intermittent operation, and equipment storage.

                    » VpCI®-649
                    A concentrated formulation combining contact and vapor-phase corrosion inhibitors with antiscalant properties for compatible freshwater and glycol closed-loop systems.

                    » VpCI®-644
                    A corrosion-inhibiting additive for ferrous and non-ferrous metals in compatible water systems containing inorganic salts, including chlorides.

                    » VpCI®-645 Marine Corrosion Inhibitor
                    A concentrated inhibitor for compatible freshwater, saltwater, brine, and other corrosive water environments containing halogens or dissolved sulfides.

                    » M-645 Saltwater and Brine Additive
                    A surface-active corrosion-inhibitor concentrate designed to displace chloride-containing water and form an oily protective film on compatible metal surfaces.

                    » VpCI®-705 Fuel Additive
                    A corrosion-preventive additive for approved gasoline, diesel, gasohol, alcohol-fuel, and fuel-storage applications.


                    Liquid, Vapor, and Interface Protection

                    A partially filled system can develop different corrosion zones:

                    • Liquid phase: Metal continuously contacted by water, oil, fuel, or process fluid.
                    • Vapor phase: Metal located above the fluid level in an enclosed system.
                    • Liquid-vapor interface: Metal near a changing fluid level, where oxygen and moisture may create aggressive corrosion conditions.

                    Selected Cortec® VpCI® additives are formulated to protect more than one of these areas. The system must remain sufficiently enclosed for vapor-phase protection to develop and remain effective.


                    Operating Systems vs. Equipment Layup

                    An additive intended for normal operation may have different performance and compatibility requirements than a product used only during storage.

                    • Operating systems require compatibility with temperature, pressure, seals, filtration, lubrication requirements, and existing treatment chemistry.
                    • Intermittent systems may require protection during repeated startup and shutdown cycles.
                    • Wet layup keeps the system filled with treated fluid during shutdown.
                    • Dry layup may use treated water during preparation followed by draining, drying, and vapor-phase preservation.
                    • Shipping and storage may require temporary treatment that can remain in place or be removed before commissioning.

                    Oil-System Compatibility

                    Before adding a corrosion inhibitor to an oil-based system, confirm compatibility with:

                    • Mineral, synthetic, or biobased base oil
                    • Oil viscosity and viscosity index
                    • Existing antiwear and extreme-pressure additives
                    • Antioxidants, detergents, and dispersants
                    • Seals, gaskets, hoses, and elastomers
                    • Bearings, gears, pumps, and hydraulic components
                    • Filtration and water-separation requirements
                    • Operating temperature and pressure
                    • Original equipment manufacturer specifications

                    Do not introduce an additive into an in-service lubricant solely on the basis of general oil compatibility. Review the complete fluid formulation and equipment requirements.


                    Water-System Compatibility

                    Water chemistry can significantly affect inhibitor performance. Important factors include:

                    • pH and alkalinity
                    • Hardness and dissolved minerals
                    • Chloride and sulfate concentration
                    • Dissolved oxygen
                    • Conductivity and total dissolved solids
                    • Glycol type and concentration
                    • Existing biocides, antiscalants, and treatment chemicals
                    • System temperature and circulation rate
                    • Ferrous and non-ferrous metals present
                    • Makeup-water and discharge requirements

                    Hydrostatic Testing and Residual Water

                    Hydrostatic testing can introduce moisture, oxygen, salts, and contaminants into newly fabricated or existing equipment. Corrosion may begin during the test or after draining if water remains trapped in low points, crevices, valves, and dead legs.

                    A properly selected additive can protect metal during the test and may help protect residual moisture after draining. The additive must be compatible with the system metallurgy, test-water chemistry, discharge requirements, and equipment commissioning plan.


                    Determining Treatment Concentration

                    Additive concentration should be based on the current technical data sheet and the specific operating conditions. Required dosage may depend on:

                    • Total system volume
                    • Carrier-fluid type
                    • Water or oil chemistry
                    • Metal types and surface condition
                    • Temperature and pressure
                    • Contaminant and chloride levels
                    • Operating or preservation period
                    • System turnover, leakage, and makeup fluid
                    • Existing treatment chemicals
                    • Required vapor-space protection

                    Under-treatment may provide inadequate protection, while excessive treatment can affect cost, residue, foaming, fluid performance, or downstream processes.


                    Mixing and Adding Corrosion Inhibitors

                    Depending on the product, an additive may be introduced into a tank, reservoir, circulating loop, blending vessel, test-water supply, or base fluid before filling.

                    For consistent treatment:

                    • Calculate the actual system or fluid volume.
                    • Confirm the recommended treatment concentration.
                    • Follow the specified order of addition.
                    • Provide sufficient agitation or circulation for uniform distribution.
                    • Avoid mixing concentrated chemicals directly unless approved.
                    • Verify pH, concentration, or other control values when required.
                    • Document the product, batch, quantity, and treatment date.

                    Testing Before Full-Scale Treatment

                    Laboratory or small-scale compatibility testing is recommended before adding a new product to an operating system. Testing may evaluate:

                    • Corrosion protection
                    • Fluid stability and separation
                    • Foaming and air release
                    • Viscosity and lubricity
                    • Filterability
                    • Seal and elastomer compatibility
                    • Scale and deposit formation
                    • Interaction with existing additives
                    • Surface residue and cleanliness
                    • Downstream process compatibility

                    Benefits of Cortec® Water and Oil Additives

                    • Internal corrosion protection for fluid-containing systems
                    • Options for water, oil, glycol, fuel, saltwater, and brine
                    • Products for operating equipment and temporary preservation
                    • Protection for ferrous and selected non-ferrous metals
                    • Selected liquid-, vapor-, and interface-phase protection
                    • Concentrated formulations for controlled dosing
                    • Protection during hydrotesting, shutdown, storage, and shipment
                    • Reduced rust deposits and corrosion-related contamination
                    • Protection for enclosed and difficult-to-reach internal surfaces
                    • Reduced risk of leakage, component damage, and premature maintenance

                    Safety, Handling, and System Approval

                    Review the current technical data sheet and safety data sheet before handling or adding any corrosion inhibitor. Confirm required personal protective equipment, ventilation, storage conditions, dilution, mixing, disposal, and spill-response procedures.

                    Obtain appropriate engineering, process, or original equipment manufacturer approval before treating critical operating equipment. Product suitability is application-specific and should not be assumed from general water or oil compatibility.


                    Related Cortec® Product Categories

                    » Coating and Fluid Additives
                    Corrosion-inhibiting additives for compatible coatings, process fluids, water-treatment formulations, and industrial systems.

                    » Enhanced Lubricants
                    Finished lubricants formulated to reduce friction, wear, and corrosion in machinery and equipment.

                    » Water Treatment
                    Corrosion-control solutions for boilers, cooling water, closed loops, process water, and industrial treatment programs.

                    » VpCI® Powders
                    Water-soluble and dry-applied corrosion inhibitors for internal spaces, hydrotesting, preservation, and equipment layup.

                    » Cleaners and Degreasers
                    Products for cleaning tanks, components, equipment, and fluid systems before treatment or preservation.


                    Why Choose ECORR Systems?

                    ECORR Systems is an Authorized Cortec® Distributor helping industrial facilities, equipment manufacturers, maintenance teams, water-treatment professionals, and system operators select corrosion-inhibitor additives for fluid systems and equipment preservation.

                    ECORR Systems can help evaluate the carrier fluid, water chemistry, base oil, system metallurgy, operating temperature, treatment objective, concentration, and required protection period to identify an appropriate Cortec® additive.


                    Frequently Asked Questions

                    What is a corrosion-inhibitor additive?

                    A corrosion-inhibitor additive is a concentrated product introduced into a compatible water, oil, fuel, glycol, or process fluid to help protect metal surfaces contacted by that fluid.

                    Can one additive be used in both water and oil?

                    Usually not. Water-soluble and oil-soluble additives have different chemistries and compatibility requirements. Select a product specifically designed for the carrier fluid and application.

                    Can Cortec® additives protect metal above the fluid level?

                    Selected VpCI® additives provide vapor-phase protection to metal above the fluid level in sufficiently enclosed systems. This capability is product-specific and should be verified before use.

                    Can an additive be used in an operating gearbox or hydraulic system?

                    Certain oil-compatible additives are designed for operating or intermittently operated equipment. Compatibility with the existing oil, additive package, seals, filters, equipment specifications, and operating conditions must be confirmed.

                    Are Cortec® additives suitable for hydrostatic testing?

                    Selected Cortec® products are formulated for hydrotesting and post-test preservation. Product selection depends on the metals, water chemistry, test duration, discharge requirements, and commissioning process.

                    How much additive should be used?

                    Dosage depends on the product, fluid volume, chemistry, contamination, temperature, metal types, and protection objective. Follow the current technical data sheet or a project-specific recommendation.

                    Can different corrosion inhibitors be mixed?

                    Do not mix additives unless compatibility has been confirmed. Incompatible chemistries may cause precipitation, separation, foaming, deposits, or reduced corrosion protection.

                    Does the treated fluid need to be removed before startup?

                    This depends on the product and equipment. Some additives can remain in the operating fluid, while preservation treatments may require draining, flushing, or replacement before commissioning.

                    Can ECORR Systems recommend a treatment concentration?

                    Yes. ECORR Systems can review the system volume, carrier fluid, water chemistry, metallurgy, operating conditions, and protection period to help identify an appropriate product and starting concentration.

                    Protect Internal Metal Surfaces with Cortec® Additives